Festo Электромотор MTR-DCI User Manual

Page 289

Advertising
background image

C. Reference – CANopen and CI objects

C-13

Festo P.BE-MTR-DCI-CO-EN en 1209a

Manufacturer hardware version

CANopen / CI

1009h

– / 00h

Var

V-string

ro

Description

Hardware version in format = “V.xx.yy” (xx = main version, yy = secondary ver-
sion)

Compare PNU 100 / object 2069h

Manufacturer software version (manufacturer firmware version)

CANopen / CI

100Ah

– / 00h

Var

V-string

ro

Description

Firmware version in format = “V.xx.yy” (xx = main version, yy = secondary ver-
sion)

Compare PNU 101 / object 206Ah

Guard time (monitoring time)

CANopen

100Ch

Var

uint16

rw

Description

Monitoring time in [ms].
To define the “Life time” for the “Life guarding protocol” the guard time in ms is
multiplied by the “Life time factor” (object 100Dh).
Default: 0 (monitoring switched off )
Value range: 0 ... 32767 (0x0000 ... 0x7FFF)

Life time factor (monitoring time factor)

CANopen

100Dh

Var

uint8

rw

Description

Multiplication factor for the guard time (object 100Ch).
Default: 0. Value range: 0 ... 255 (0x00 ... 0xFF)

COB-ID Emergency object

CANopen

1014h

Var

uint32

rw

Description

COB ID of Emergency object (EMCY); see DS 301 specification.
The Emergency protocol is supported.
Default: 128 + Node-ID (0x80 + Node-ID)

Inhibit time EMCY

CANopen

1015h

Var

uint16

rw

Description

Inhibit time for the emergency message. The value is multiplied by 100 μs.
Default: 0

Advertising