w w w . d i g i e m b e d d e d . c o m

3 4 1

E t h e r n e t C o m m u n i c a t i o n M o d u l e

D19

R/W

ERXINIT

0

Enable initialization of RX buffer descriptors

0

Do not initialize

1

Initialize

When set, causes the

RX_RD

logic to initialize the internal

buffer descriptor registers for each of the four pools from
the buffer descriptors pointed to by RXAPTR, RXBPTR,
RXCPTR, and RXDPTR. This is done as part of the RX
initialization process. RXINIT is set in the Ethernet
General Status register (see page 344) when the
initialization process is complete, and ERXINIT must be
cleared before enabling frame reception from the MAC.

The delay from ERXINIT set to RXINIT set is less than
five microseconds.

D18:16

N/A

Reserved

N/A

N/A

D15:14

R/W

PHY_MODE

00

Ethernet interface mode

00

10/100 Mbit MII mode

01

10/100 Mbit RMII mode

10

Reserved

11

Reserved

Identifies what type of Ethernet PHY is attached to
NS9750. NS9750 supports two styles of Ethernet PHY:
MII and RMII.

This field should be changed only while the MAC is reset.

D13

N/A

Reserved

N/A

N/A

D12:11

R/W

Not used

0

Always write as 0.

D10

R/W

RXALIGN

0

Align RX data

0

Standard receive format. The data block immediately
follows the 14-byte header block.

1

The receiver inserts a 2-byte padding between the 14-
byte header and the data block, causing longword
alignment for both the header and data blocks.

D09

R/W

MAC_HRST

1

MAC host interface soft reset

0

Restore MAC, STAT, SAL, RX_WR, and TX_RD to
normal operation.

1

Reset MAC, STAT, programmable registers in SAL,
RX_WR, and TX_RD. Keep high for minimum of
5

μsec to guarantee that all functions get reset.

Bits

Access

Mnemonic

Reset

Description

Table 206: Ethernet General Control Register #1