I 2 C r e g i s t e r s

5 4 8

N S 9 7 5 0 H a r d w a r e R e f e r e n c e

Command Transmit Data register

Address: 9050 0000

The Command Transmit Data (

CMD_TX_DATA_REG

) register is the primary interface

register for transmission of data between the NS9750 BBus and I

2

C bus. This register

is write only.

Register bit assignment

Bits

Access

Mnemonic

Reset

Description

D31:16

N/A

Reserved

N/A

N/A

D15

W

PIPE

00

hex

Pipeline mode

Must be set to 0.

D14

W

DLEN

00

hex

I

2

C DLEN port (

iic_dlen

)

Must be set to 0.

D13

W

TXVAL

00

hex

Provide new transmit data in

CMD_TX_DATA_REG

(

tx_data_val

).

D12:08

W

CMD

00

hex

Command to be sent (see "Master and slave module
commands," beginning on page 546)

D07:00

W

TXDATA

00

hex

Transmit data to I

2

C bus.

Table 337: CMD_REG and TX_DATA_REG

TXVAL

CMD

TXDATA

13

12

11

10

9

8

7

6

5

4

3

2

1

0

15

14

PIPE

DLEN

31

29

28

27

26

25

24

23

22

21

20

19

18

17

16

30

Reserved