Register bit assignment, Table 215: collision window/retry register – Digi NS9750 User Manual

Page 380

Advertising
background image

E t h e r n e t C o n t r o l a n d S t a t u s r e g i s t e r s

3 5 6

N S 9 7 5 0 H a r d w a r e R e f e r e n c e

Register bit assignment

Bits

Access

Mnemonic

Reset

Description

D31:14

N/A

Reserved

N/A

N/A

D13:08

R/W

CWIN

0x37

Collision window

Programmable field indicating the slot time or collision
window during which collisions occur in properly
configured networks. Because the collision window
starts at the beginning of transmissions, the preamble and
SFD (start-of-frame delimiter) are included.

The default value (0x37 (55d)) corresponds to the frame
byte count at the end of the window.

D07:04

N/A

Reserved

N/A

N/A

D03:00

R/W

RETX

0xF

Retransmission maximum

Programmable field specifying the number of
retransmission attempts following a collision before
aborting the frame due to excessive collisions. The
802.3u standard specifies the

attemptLimit

to be

0xF (15d)

.

Table 215: Collision Window/Retry register