7 0 2

N S 9 7 5 0 H a r d w a r e R e f e r e n c e

Granularity Count register

Address: 9040 0168

The Granularity Count register controls the value of the granularity counter for
automatic processing modes.

Note:

According to the IEEE 1284 standards spec, the peripheral has a T

p

(500ns)

minimum setup pulse width for some signals. If, for example, the BBus is
set to run at 50 MHz (20ns clock period), the Granularity Count register
should be set to 25 (

0x19

)

[500ns / 20ns]

.

Bits

Access

Mnemonic

Reset

Description

D31:08

R

Reserved

0x0

N/A

D07:00

R/W

grn

0x0

Granularity counter

Determines the number of BBus clock periods between
peripheral signal changes on the IEEE 1284 bus.

Table 411: grn — Granularity Count register

grn

13

12

11

10

9

8

7

6

5

4

3

2

1

0

15

14

31

29

28

27

26

25

24

23

22

21

20

19

18

17

16

30

Reserved

Reserved