MII Management Address register

Address: A060 0428

Register bit assignment

D01

R/W

SCAN

0

Automatically scan for read data

Set to 1 to have the MII Management module perform
read cycles continuously. This is useful for
monitoring link fail, for example.

Note:

SCAN must transition from a 0 to a 1 to
initiate the continuous read cycles.

D00

R/W

READ

0

Single scan for read data

Set to 1 to have the MII Management module perform
a single read cycle. The read data is returned in the
MII Management Read Data register after the BUSY
bit in the MII Management Indicators register has
returned to a value of 0.

Note:

READ must transition from a 0 to a 1 to
initiate a single read cycle.

Bits

Access

Mnemonic

Reset

Description

Table 219: MII Management Command register

Bits

Access

Mnemonic

Reset

Description

D31:13

N/A

Reserved

N/A

N/A

Table 220: MII Management Address register

Reserved

13

12

11

10

9

8

7

6

5

4

3

2

1

0

15

14

31

29

28

27

26

25

24

23

22

21

20

19

18

17

16

30

DADR

Reserved

Reserved

RADR