L C D t i m i n g

8 2 2

N S 9 7 5 0 H a r d w a r e R e f e r e n c e

LCD timing

Note:

All AC characteristics are measured with 10pF, unless otherwise noted.

Table 474 describes the values shown in the LCD timing diagrams (Figure 129 through
Figure 135).

Parm

Description

Register

Value

Units

L1

Horizontal front porch blanking

LCDTiming0

HFP+1

CLCP periods

L2

Horizontal sync width

LCDTiming0

HSW+1

CLCP periods

L3

Horizontal period

N/A

L1+L2+L15+L4

CLCP periods

L4

Horizontal backporch

LCDTiming0

HBP+1

CLCP periods

L5

TFT active line

LCDTiming0

16*(PPL+1)
(see note 3)

CLCP periods

L6

LCD panel clock frequency

LCDTiming1

For BCD=0:
CLCDCLK/(PCD+2)

For BCD=1:
CLCDCLK (see note 1)

MHz

L7

TFT vertical sync width

LCDTiming1

VSW+1

H lines

L8

TFT vertical lines/frame

N/A

L7+L9+L10+L11

H lines

L9

TFT vertical back porch

LCDTiming1

VBP

H lines

L10

TFT vertical front porch

LCDTiming1

VFP

H lines

L11

Active lines/frame

LCDTiming1

LPP+1

H lines

L12

STN HSYNC inactive to
VSYNC active

LCDTiming0

HBP+1

CLCP periods

L13

STN vertical sync width

N/A

1

H lines

L14

STN vertical lines/frame

N/A

L11+L16

H lines

L15

STN active line

LCDTiming2

CPL+1 (see note 4)

CLCP periods

L16

STN vertical blanking

LCDTiming1

VSW+VFP+VBP+1

H lines

L17

STN CLCP inactive to HSYNC
active

LCDTiming0

HFP+1.5

CLCP periods

Table 474: LCD timing parameters