Table 473 describes the values shown in the I

2

C timing diagram (Figure 128).

Figure 128: I

2

C timing

Standard mode

Fast mode

Parm

Description

Min

Max

Min

Max

Unit

C1

iic_sda to iic_scl START hold time

4.0

0.6

μs

C2

iic_scl low period

4.7

1.3

μs

C3

iic_scl high period

4.7

1.3

μs

C4

iic_scl to iic_sda DATA hold time

0

0

μs

C5

iic_sda to iic_scl DATA setup time

250

100

ns

C6

iic_scl to iic_sda START setup time

4.7

0.6

μs

C7

iic_scl to iic_sda STOP setup time

4.0

0.6

μs

Table 473: I

2

C timing parameters