Configuration register, C bus clock timing is programmable by the, Value – Digi NS9750 User Manual

Page 576

Advertising
background image

I 2 C r e g i s t e r s

5 5 2

N S 9 7 5 0 H a r d w a r e R e f e r e n c e

Configuration register

Address: 9050 000C

The Configuration register controls the timing on the I

2

C bus. This register also

controls the external interrupt indication, which can be disabled.

The I

2

C bus clock timing is programmable by the

scl_ref

value (

D08:00

). The timing

parameter for standard mode is as follows:

I

2

C_bus_clock = clk / ((CLREF*2) + 4 + scl_delay)

clk = cpu_clk/4

Note:

In noisy environments and fast-mode transmission, spike filtering can be
applied to the received I

2

C data and clock signal. The spike filter

evaluates the incoming signal and suppresses spikes. The maximum length
of the suppressed spikes can be specified in the spike filter width field of
the Configuration register (see page 553).

The timing parameter for fast-mode is as follows:

I

2

C_bus_clock = (4 / 3) x (clk / ((CLREF*2) + 4 + scl_delay))

scl_delay

is influenced by the SCL rise time.

Register bit assignment

Bits

Access

Mnemonic

Reset

Description

D31:16

N/A

Reserved

N/A

N/A

D15

R/W

IRQD

0

Mask the interrupt to the ARM CPU (

irq_dis

)

Must be set to 0.

Table 341: Configuration register

13

12

11

10

9

8

7

6

5

4

3

2

1

0

15

14

31

29

28

27

26

25

24

23

22

21

20

19

18

17

16

30

Reserved

CLREF

IRQD

TMDE VSCD

SFW

s