6 2 7

S e r i a l C o n t r o l M o d u l e : U A R T

The next tables show sample UART baud rates. These rates can be produced using the
recommended PLL reference oscillator frequency of 29.4912 MHz and setting the
CLKMUX field in the Bit Rate register to 0. The first table shows the range of available
baud rates when the PLLND field in the PLL Configuration register is at least

0x13

. The

second table shows the range of available baud rates when the PLLND field is less
then

0x13

.

D20:19

R/W

TDCR

00

Transmit clock divide rate

00

Not valid for UART

01

8x clock mode

10

16x clock mode

11

32x clock mode

Determines the divide ratio for the transmitter clock.

D18:17

R/W

RDCR

00

Receive clock divide rate

00

Not valid for UART

01

8x clock mode

10

16x clock mode

11

32x clock mode

Determines the divide ratio for the receiver clock.

D16

R/W

Not used

0

Always write 0 to this field.

D15

R/W

Not used

0

Always write 0 to this field.

D14:00

R/W

N

0x0000

Divisor value

Defines the divisor value used in the bit-rate generator to
determine effective frequency of the bit-rate generator.

The divisor value for UART operation is defined as
follows:

N = ((F

CLK

/ (UM * BR)) – 1)

where:

F

CLK

= Determined by CLKMUX field

UM = UartMode = 8, 16, or 32 as defined by RDCR

and TDCR

BR = BaudRate = Required baud rater

See Table 371 and Table 372 for examples.

Bits

Access

Mnemonic

Reset

Description

Table 370: Serial Channel B/A/C/D Bit-rate register

Advertising