no ethernet cfm enable

10.2 Configuring the CFM frame ethertype

Use the command to configure the ethertype for CFM frames.

Command Syntax

ethernet cfm type TYPE
no ethernet cfm type

Command Mode

Configure mode

Default

The default ethertype is 0x8902.

Usage

The Ethernet type of the CFM frames. The default value is 0x8902.

Examples

Switch#configure terminal
Switch(config)# ethernet cfm type 8902

Switch#configure terminal
Switch(config)# no ethernet cfm type

Related Commands

10.3 Creating a Maintenance Domain

Use the command to create an MD within which you can manage Ethernet traffic. Ensure you specify the
level for each MD. The levels separate MDs from each other and provide different areas of functionality.

Command Syntax

ethernet cfm domain DOMAIN_NAME level LEVE
no ethernet cfm domain DOMAIN_NAME level LEVE