10.5 Configuring a Maintenance End Point
Use the command to define an MEP within an MA. Each MEP and remote MEP must have a unique ID
within an MA. If two or more MEPs share the same ID, CFM raises an event indicating a duplicate MEP
exists in the MA.
Command Syntax
ethernet cfm mep level LEVEL (down|up) mpid MEPID vlan VLANID
no ethernet cfm mep level LEVEL (down|up) mpid MEPID vlan VLANID
Command Mode
Interface mode
Default
None
Usage
This command is used to Create a local MEP.
Examples
Related Commands
ethernet cfm domain DOMAIN_NAME level LEVE
service CSI_ID vlan VLAN_ID
10.6 Configuring a remote Maintenance End Point
Use this command to define a remote maintenance end point (MEP) within a maintenance domain,and
enable to crosscheck the RMEP.
Command Syntax
mep crosscheck mpid MEPID vlan VLANID (|mac MAC)
no mep crosscheck mpid MEPID vlan VLANID (|mac MAC)
Command Mode
Configure mode
Default