10 configuring a maintenance intermediate point, 11 cfm loopback tests – CANOGA PERKINS CanogaOS Command Reference User Manual
Page 194
CanogaOS Command Line Reference
Revision 1.02
Proprietary & Confidential Canoga Pertkins Metro Ethernet Switches
Page 194 of 855
None
Examples
Switch#configure terminal
Switch(config)# ethernet cfm cc level 7 vlan 30 intreval 10000
Related Commands
10.10 Configuring a Maintenance Intermediate Point
Use this command to define an MIP.
Command Syntax
ethernet cfm mip level LEVEL
no ethernet cfm mip level LEVEL
Command Mode
Interface mode
Default
No MIPs are configured.
Usage
1) This command creates a MIP for every VLAN allowed on an interface, but you must first create a
domain using the ethernet cfm domain command. If you do not have a domain configured at the
same level, the ethernet cfm mip level command is rejected.
2) You cannot configure a MIP at a level lower than the level of already configured maintenance end
points (MEPs) on an interface.
3)
Examples
Switch#configure terminal
Switch(config)# ethernet cfm mip level 7
Related Commands
10.11 CFM loopback tests
Use the command to issue CFM loopback messages and verify that remote MEPs or MIPs are accessible.