Related Commands

logging server

40.71 logging server facility

To configure the syslog facility in which error messages are sent, use the logging server facility
command in global configuration mode. To revert to the default of local7, use the no form of this
command.


Command Syntax

logging server facility facility-type
no logging server facility

facility-type

Syslog facility. See the “Usage” section of this command reference entry
for descriptions of acceptable keywords.


Command Mode

Global configuration


Default

Default is local7.

Usage

The following table describes the acceptable keywords for the facility-type argument.


Examples

The following is sample output from the logging file command.
Switch(config)# logging server facility local3


Related Commands

logging server

40.72 logging server severity

To set severity level while writing logs into servers, use the logging server severity command in
global configuration mode. To revert to the default severity level, use the no form of this command.


Command Syntax

logging server severity {alert | critical | debug | emergency | error | information | notice | warning
| severity-level}
no logging server severity

{0 | emergency}

System is unusable.