4 Parameters

4.1.1 Parameter Classifications

4-2

4.1

Overview of Parameters

This section outlines the parameters critical to Module motion functions. The user must read
this section to gain a basic understanding of these parameters.

4.1.1

Parameter Classifications

„

Overview

Parameters are specific constants needed for Module motion functions. Set these parameters
to values appropriate for machine specifications as well as for applicable Servodrive (Servo-
motor + SERVOPACK) performance.

Use a MPE720 Programming Device to create and edit parameters.

„

Parameter List

Parameters are classified into the following four types.

Classification

Register No.

Description

Motion Fixed
Parameters

No registers

These parameters set machine, Servomotor,
encoder, and other mechanical conditions. They
are not normally changed once they are set, and
they cannot be changed while the system is run-
ning.

Motion Setting
Parameters

OW††00 to
OW††3F

These parameters are used to provide commands
to the servo control section. They can be set from
a motion program or ladder logic program while
the system is running.

Motion Monitoring
Parameters

IW††00 to
IW††3F

These parameters are servo monitor data reported
by the servo control section. They can serve as ref-
erence for motion programs or ladder logic pro-
grams.

Motion Servo
Parameters

Cn-0001 to Cn-003F

These parameters are the SERVOPACK parame-
ters that are set on the Motion Parameter Setting
Window.
Note: The servo parameters are required only for

the SVB-01 Module.