2 sgda servopack connections, Connection example, Parameter settings – Yaskawa MP920 Motion Module User Manual

Page 383: Cn-12 (time lag from brake reference to servo off)

Advertising
background image

9.1 Vertical Axis Control

9-3

9

9.1.2

SGDA SERVOPACK Connections

„

Connection Example

* 1. Brake control relay
* 2. Brake power supplies are available in either 200 or 100-V models.

„

Parameter Settings

The following section shows SERVOPACK parameters for brake control.

Cn-12 (Time Lag from Brake Reference to Servo OFF)

Use the following parameter if brake ON timing causes the machine to move slightly due to
gravity or other forces.

Set the brake control output signal /BK and servo OFF operation (Servomotor output stop)
timing when you use a Servomotor with brake.

MAX

50 mA

/BK

SG-COM

Brake power supply

Blue or yellow

White

Black

Red

BK-RY

+24 V

-7

-10

R

T

1CN

U
V

W

2CN

Motor Flags

1
2
3
4
5
6

BK-RY

AC

DC

PG

M

BK

1 2 3
4 5 6

Power supply

SGDA SERVOPACK

SGM (SGMP) Servomotor

with brake

∗1

∗2

Cn-12

Time Lag from Brake
Reference to Servo OFF

Units:
10 ms

Setting Range:
0 to 50

Factory Setting:
0

Speed/torque
control and po-
sition control

/S-ON input
(1CN-14)

/BK output

Servo ON/OFF
operation
(Servomotor ON)

Brake
released

Servo ON

Servomotor
ON

Brake holding

Servo OFF

Servomotor OFF

Servo OFF
lag time

Cn-12