9 Application Precautions

9.3.1 Overview

9-16

9.3

Software Limit Function

This section describes the software limit function.

9.3.1

Overview

The software limit function is used to set upper and lower limits in fixed parameters for
machine range of movement so the controller can constantly monitor the operating range of
the machine. The function prevents machine overrun or damage due to incorrect operation
or incorrect references in the motion program.

9.3.2

Fixed Parameter Settings

The following fixed parameters must be set to use the software limit function.

Set the upper and lower software limits for the machine coordinate system.

The machine coordinate system is determined by returning to the zero point.

The software limit function is implemented after the machine returns to the zero point.

Be sure to return to the zero point after power is turned ON.

Software limit
(lower limit)

Software limit
(upper limit)

Overtravel in the
reverse direction

Overtravel in the
forward direction

(Range of machine movement)

Servo-
motor

Parameter

No.

Name

Units

Setting Range

17

Motion Controller Function Selection Flags

Bit 7: Positive Software Limit Selection

0: Enabled, 1: Disabled

Bit 8: Negative Software Limit Selection

0: Enabled, 1: Disabled

27

Positive Software Limit

1 = Refer-
ence units

-2147483648 to
2147483647

29

Negative Software Limit

1 = Refer-
ence units

-2147483648 to
2147483647