10.3 Counter Modes

10-27

10

„

Setting Frequency Measurement Functions

Use the following settings when using the Counter Module for frequency measurement.

Fixed Parameter Settings

Specify Frequency Measurement in fixed parameter 06 (Counter Mode).

Set other parameters to suit the operating conditions.

I/O Data Settings

I/O data will be displayed as shown below when the counter mode is set to Frequency Mea-
surement.

Table 10.8 Input Data

Name

Register No.

Range

Meaning

Status

OW††††

Each bit

Increment Pulse

OL†††† + 2

0 to

± 2

31

-1

1 = 1 pulse

Hardware Counter

OL†††† + 4

0 to

± 2

31

-1

1 = 1 pulse

Detection Frequency

OL†††† + 6

0 to

± 2

31

-1

1 = 1 pulse

Average Frequency

OL†††† + 8

0 to

± 2

31

-1

1 = 1 pulse