10 CNTR-01 Module Specifications and Handling

10.3.1 Reversible Counter Mode

10-22

10.3 Counter Modes

This section explains the counter modes for the CNTR-01 Module.

10.3.1

Reversible Counter Mode

The Reversible Counter Mode increments or decrements the count according to pulse A and
pulse B inputs. Counting is interrupted during pulse C input.

Note: Fixed parameter 11 can be used to stop or start counting for pulse C

inputs.

The following functions are possible in Reversible Counter Mode depending on output reg-
ister designations.

• Count Prohibited: Disables counting.
• Count Preset: Forcibly changes count values.
• PI Latch Detection: Writes the counter value to memory when an external signal is input.
• Coincidence Detection: Outputs an external output signal when the Set Coincidence

Detection output register value and the current counter value are the same.

* 1. Current counter value = Hardware counter (IL†††† + 4)
* 2. Count preset = Count preset data (OL†††† + 2)

n1

n2

n3

n4

n5

n6

n7

n1

n2

n3

n4

n5

n6

n7

MIN

(80000000H)

MIN

(80000000H)

UP

UP

DOWN

UP

DOWN

DOWN

Ts

0

(+)

(-)

Ts: Scan setting

MAX (7FFFFFFFH) MAX (7FFFFFFFH)

Count
preset

*2

Count
preset

*2

Count register

Pulse A and pulse B

Pulse C terminal (positive logic)

Pulse C terminal (negative logic)

Current counter value

*1

Stop

Stop

Stop

Advertising