Yaskawa MP920 Motion Module User Manual

Page 387

Advertising
background image

9.1 Vertical Axis Control

9-7

9

When using a Servomotor with brake, be sure to set the brake timing when the /S-ON signal
(1CN-40) is input while the Servomotor is running or when an alarm turns the servo OFF.

The Servomotor brake is designed only for holding purposes. The brake must be applied with proper
timing when the Servomotor stops. Adjust this parameter while monitoring machine operation.

/S-ON input
(1CN-40) or an
alarm turns the
power supply
OFF

Motor speed
(r/min)

Pn-507

/BK output

Brake
released

Servo ON

Dynamic brake
or free run stop
(Pn001.0)

Pn-508

Brake holding

Servo OFF

INFO

Advertising