10 CNTR-01 Module Specifications and Handling
10.5.1 Connections to Pulse Generators
10-34
10.5 CNTR-01 Counter Module Connections
This section explains external I/O terminal connections.
10.5.1
Connections to Pulse Generators
12-VDC Open Collector Output
The connections to a 12-VDC open collector output pulse generator are shown in the follow-
ing diagram.
680
Ω
HCPL0611
0.033
12VA1
12PA1
(DI_COM)
(DI_COM)
(DI_COM)
1.5k
1.5k
680
Ω
HCPL0611
0.033
12VB1
12PB1
1.5k
1.5k
680
Ω
HCPL0611
0.033
12VC1
12PC1
1.5k
1.5k
1k
24PC1
Connector shell
Channels 2 to 4
CN2
+12V
0V
12-VDC
power
supply
+
-
CNTR-01
Pulse Generator
Phase A
Channel 1