4.1 Overview of Parameters

4-3

4

„

Editing Parameters

The following table describes the procedures used to create, edit, or change parameters.

4.1.2

Modules and Motion Parameter Registers

The motion parameter register numbers (I register numbers and O register numbers) will
vary with the motion number and the individual axis (axis 1 to 16).

The following equation is used to determine motion parameter register numbers.

• Motion register number (IW†††† and OW††††) = Motion number offset + axis

offset.

The following are Module number offsets listed by Module number.

The following equations gives the axis offsets according to the axis number.

Axis offset = (axis number-1)

×

40H (64 words)

Setting Method

Procedure

Applicable Parameters

Personal Computer
Programmer

Parameters are edited in the Definitions
Folder from the Setting Window.

Fixed Parameters
Setting Parameters
Servo Parameters

Motion Programs

Motion programs can be used to set setting
parameters (output registers OW††00 to
OW††3F) with assignment statements.

Setting Parameters

Ladder Logic
Programs

Parameters can be set directly from ladder
logic programs.

Setting Parameters

Module No.

Offset Value

Module No.

Offset Value

1

C000

9

E000

2

C400

10

E400

3

C800

11

E800

4

CC00

12

EC00

5

D000

13

F000

6

D400

14

F400

7

D800

15

F800

8

DC00

16

FC00