8 Troubleshooting

8.2.1 Alarm IL††22

8-16

„

Servo Drive Synchronous Communications Error

„

Servo Drive Communications Error

SVA-01A

SVA-02A

SVB-01

PO-01

Not supported

Not supported

Supported

Not supported

Detection Timing

• Detected by the communications control section during synchronous communications between

the controller and MECHATROLINK SERVOPACK.

Alarm Processing

• The command that is being executed will be terminated.

Errors and Causes

• An error occurred during MECHATROLINK communications.

(Cable disconnected, noise on the communications path)

Action Taken

• Check the MECHATROLINK cable and then reset the alarm.

SVA-01A

SVA-02A

SVB-01

PO-01

Not supported

Not supported

Supported

Not supported

Detection Timing

• Detected by the communications control section when a controller and MECHATROLINK

SERVOPACK are connected.

Alarm Processing

• The command that is being executed will be terminated.
• The SERVOPACK will turn OFF.

Errors and Causes

• MECHATROLINK communications stopped.

(Cable disconnected, noise on the communications path)

Action Taken

• Check the MECHATROLINK cable and then reset the alarm.