3 po-01 parameters, 1 motion fixed parameters – Yaskawa MP920 Motion Module User Manual
Page 333

7.3 PO-01 Parameters
7-31
7
7.3
PO-01 Parameters
7.3.1
Motion Fixed Parameters
Motion fixed parameters cannot be changed when bit 0 of motion setting parameter No. 2: RUN Com-
mand Settings (OW01) is ON. Position data and other data will be initialized if a motion fixed
parameter is changed.
IMPORTANT
Table 7.9 Motion Fixed Parameters
No. Name
Description
Factory
Setting
1
Axis Selection
(USESEL)
Set whether an axis is used or not.
0: Not used.
1: Used.
If an axis is set to be not used (= 0), then that axis will not be controlled and
IW00 to IW3F monitoring parameters will not be updated. “0” will
stored at IW00 RUN Status.
0
(Not used)
2 to
6
Not used.
−
−
7
Rated Motor Speed
Setting (NR)
Set motor speed at rated (100%) operation in 1 r/min units. Set this parameter
based on the specifications of the Servomotor that is used.
100
8 to
13
Not used.
−
−