8 Troubleshooting

8.1.1 Description of Motion Alarms

8-4

SVB-01

Servo Drive alarm code
(SVALARM)
IW

24

Run Status (RUNSTS)
IW

00

Bit1: PRMERR

Motion setting parameter setting error

Bit2: FPRMERR

Motion fixed parameter setting error

Out of range parameter number (ERNO)
W

0F

Alarms (ALARM)
IL

22

Bit0: SVERROR Servopack error

Bit1: OTF

Positive overtravel

Bit2: OTR

Negative overtravel

Bit3: SOTF

Positive software limit

Bit4: SOTR

Negative software limit

Bit5: SVOFF

Servo power OFF

Bit17: ABSOVER ABS encoder count exceeded

00: Absolute data error

02: Parameter

destruction

10: Overcurrent

11: Ground

fault

F3: Power

loss

Motion program alarms

Alarm output status
specified from the Group
Definitions Window

Program alarms

2h: Zero division error

10h:

Circumference

specified

for

radius

specification

11h: Interpolation feed speed exceeded

12h:

No

interpolation

feed

speed

20h: REG data error

Axis alarms

80h: Logical axis use disabled

81h: POSMAX exceeded in infinite length

aixs

designation

82h: Distance the axis moved exceeded

LONG_MAX

89h:

Beyond

the

ACC/SCC/DCC

setting

range

Displays the execute/error status of Motion
Modules: 7-segment LED indicator

Motion Module LED indicator