Yaskawa MP920 Motion Module User Manual

Page 56

Advertising
background image

2 Motion Control

2.3.1 Prerequisites for Position Control

2-30

Table 2.12 shows the meanings of the above parameters and gives some setting examples.

Table 2.12 Electronic Gear Parameters and Constant Table

Servo Fixed

Parameter No.

Name

Description

Initial

Value

No.19

Travel Distance
Per Machine
Rotation

• This parameter shows the load travel distance for each rotation of the load

axis. Sets the load travel distance value divided by the minimum reference
unit.

• Some examples of the load travel distance are shown below.

10000

Travel Distance Per

Machine Rotation

Load Configuration Examples

P [mm]

Ball
screw

360 [

° ]

Round
table

πD [mm]

Belt

• No.19 setting range: 1 to 2

31

-1[1 = 1 reference unit]

Setting Examples

• Load travel distance per load axis rotation = 12 mm
• Minimum reference unit = 0.001 mm [reference unit: mm, digit number

after decimal point: 3]

No.19 =

Load travel distance per load axis rotation

Minimum reference unit

P = Ball screw pitch

P

One rotation = 360

°

π D

D

No.19 =

= 12000

12 mm

0.001 mm

Advertising