4 Parameters

4.2.1 Motion Fixed Parameters

4-8

18

Number of Digits
Below Decimal
Point
(DECNUM)

0 to 5
(Default = 3)

Sets the number of digits right of
the decimal point in commands.
(Example)
With 3 digits right of the decimal
point
mm: 1 reference unit = 0.001
mm
deg: 1 reference unit = 0.001 deg
inch: 1 reference unit = 0.001
inch

Minimum reference unit
is determined by this
parameter as well as by
the Reference Unit
Selection (see fixed
servo parameter no. 17.).

19

Travel Distance
Per Machine
Rotation
(PITCH)

1 to 2

31

-1

(Default = 10000)

1 = 1 reference unit

21

Servomotor Gear
Ratio
(GEAR_
MOTOR)

1 to 65535
(Default = 1)

1 = 1 rotation

22

Machine Gear
Ratio
(GEAR_
MACHINE)

1 to 65535
(Default = 1)

1 = 1 rotation

23

Infinite Length
Axis Reset
Position
(POSMAX)

1 to 2

31

-1

(Default =
360000)

1 = 1 reference unit

25

Maximum Num-
ber of Absolute
Encoder Turns
(MAXTURN)

1 to 2

31

-1

(Default = 99999)

1 = 1 rotation

27

Positive Software
Limit
(SLIMP)

-2

31

to 2

31

-1

(Default = 2

31

-1)

1 = 1 reference unit

29

Negative Software
Limit
(SLIMN)

-2

31

to 2

31

-1

(Default = -2

31

)

1 = 1 reference unit

31

Zero Point Return
Method
(ZRETSEL)

0 to 7
(Default = 0)

0: DEC1 + Phase-C pulse

1: ZERO

2: DEC1 + ZERO

3: Phase-C pulse

4: DEC2 + ZERO

5: DEC1 + LMT + ZERO

6: DEC2 + Phase-C pulse

7: DEC1 + LMT + Phase-C pulse

32

Backlash
Compensation
(BKLSH)

0 to 32767
(Default = 0)

1 = 1 reference unit

Table 4.2 Motion Fixed Parameters (cont’d)

No.

Name

Setting Range/

Bit Name

Meaning

Remarks

SVA

-01A

SVA

-02

A

SVB

-01

PO-

01