Yaskawa MP920 Motion Module User Manual

Page 265

Advertising
background image

6 SVB Module Specifications and Handling

6.2.2 Motion Setting Parameters

6-30

21

Filter Time
Constant
Setting
(NNUM)

OW††14

• Average move

filter 0 to 5100

• Exponential

acceleration
speed
0 to 5100

Set the time constant used for a moving average filter or
exponential acceleration/deceleration filter.
When Motion Command Code (OW††20) is set to 12,
the value set in this parameter is reflected as follows:

1. Reflected in the SERVOPACK Cn-0026 constant

(Average Move Time) when bits 4 to 7 of OW††21
are set to 2 (Average Movement Filter).

2. Reflected in the SERVOPACK Cn-002E constant

(Exponential Acceleration Time Constant) when bits
4 to 7 of OW††21 are set to 1 (Exponential Filter).

0

22

Speed Refer-
ence Setting
(NREF)

OW††15

-32768 to 32767

Set the rapid traverse speed in 0.01% units (percentage of
the rated motor speed) when the Speed Reference Selec-
tion (OB††1D) is set to 1.

0

23 to

29

Not used.

OL††16 to
OW††1C

Set to “0.”

0

30

Speed Loop
Gain (Kv)

OW††1D

1 to 20000

Set the speed loop gain for MECHATROLINK SERVO-
PACKs.
The value set in this parameter is reflected in the SERVO-
PACK Cn-0004 constant (Speed Loop Gain) when
Motion Command Code (OW††20) is set to 14.

0

Table 6.3 Motion Setting Parameters (cont’d)

No.

Name

Register

Number

Setting Range/

Bit Name

Description

Factory

Setting

Advertising