Out data (output data), Status (operating status) – Yaskawa MP920 Motion Module User Manual

Page 417

Advertising
background image

10 CNTR-01 Module Specifications and Handling

10.2.3 Setting I/O Data

10-16

„

Out Data (Output Data)

Output data is used as references for the Counter Module. It is output to the Counter Module
at the beginning of each scan.

Note:

√: Supported, −: Not supported

„

Status (Operating Status)

Note:

√: Supported, −: Not supported

Name

Register Number

Range

Meaning

Reversible

Counter

Interval

Counter

Frequency

Measurement

Operating Mode

OW††††

Individual
bits

1 = 1 time
0 = No
averaging

Averaging Count
Setting

OW†††† + 1

0 to 255

1 = 1 pulse

Count Preset Data

OL†††† + 2

0 to

±

2

31

-1

1 = 1 pulse

Set Coincidence
Detection

OL†††† + 4

0 to

±

2

31

-1

1 = 1 pulse

Reserve

OW†††† + 6 to
OW†††† + F

Bit No.

Name

Reversible

Counter

Interval

Counter

Frequency

Measurement

0

Data Setting Error

1

Fixed Parameter Setting Error

2

Count Value Preset

3

PI Latch Detected (1: PI latch detected)

4

Pulse A/B 0 (1: Within feedback pulse

±1)

5

Coincidence Detected
(1: Coincidence detection signal ON)

6

Pulse A Status (1: High, 0: Low)

7

Pulse B Status (1: High, 0: Low)

8

Pulse C Status (1: High, 0: Low)

9

Writing Fixed Parameter
(Online parameters are being written)

10

Not used.

11

Not used.

12

Not used.

13

Not used.

14

Not used.

15

Module Ready (1: Started normally)

Advertising