8.2 Alarms and Actions Taken

8-19

8

„

Status Monitor (IW††01)

The status of a MECHATROLINK SERVOPACK can be monitored through monitoring
parameter IW††01 for an SVB-01 Module.

Bit No.

Alarm Name

Meaning

Bit 0

Alarm (ALARM)

0: No alarm
1: Alarm

Bit 1

Warning (WARNG)

0: No warning
1: Warning

Bit 2

Command Ready
(CMDRDY)

0: Receive command disabled (busy)
1: Receive command enabled (ready)

Bit 3

Servo ON (SVON)

0: Servo OFF (base blocking)
1: Servo ON (base blocking canceled)

Bit 4

Main Power Supply
ON (PON)

0: Main power supply OFF
1: Main power supply ON

Bit 5

Machine Lock
(MLOCK)

0: Machine lock OFF
1: Machine lock ON

Bit 6

Zero Point (ZPOINT)

0: APOS (absolute position) outside zero point range
1: APOS (absolute position) within zero point range

Bit 7

Positioning Complet-
ed (PSET)

0: Command distribution not completed or APOS outside

positioning completed range

1: Command distribution completed and APOS within posi-

tioning completed range

Bit 8

Distribution Complet-
ed (DEN)

0: Positioning reference is being distributed
1: Positioning reference has been distributed

Bit 9

Torque Limiting
(T_LIM)

0: No torque limiting
1: Torque limiting

Bit 10

Latch Completed
(L.SOT)

0: Latch not completed
1: Latch completed

Bit 11

Positioning Proximity
(NEAR)

0: APOS outside positioning proximity range
1: APOS within positioning proximity range

Bit 12

Forward Software
Limit (P-SOT)

0: Below the forward software limit
1: Above the forward software limit

Bit 13

Reverse Software
Limit (N-SOT)

0: Below the reverse software limit
1: Above the reverse software limit

Bit 14

Reserved by system.

Bit 15

Reserved by system.

Advertising