6.2 SVB-01 Parameters

6-19

6

21

Servomotor Gear
Ratio
(GEAR_MOTOR)

These parameters determine the gear ratio between the motor and the load.
The following two values are set for a configuration in which the load shaft will
turn n times in response to m turns of the motor shaft.

• Gear ratio at Servomotor: m
• Gear ratio at load: n

Setting Example

In the above example, the reduction ratio is n/m, or 3/7

× 4/9 = 4/21. The follow-

ing setting would thus be made.
Servomotor Gear Ratio: 21
Load Gear Ratio: 4

1

22

Machine Gear Ratio
(GEAR_MACHINE)

1

23

Infinite Length Axis
Reset Position
(POSMAX)

Set the reset position for a rotation when infinite length axis is set. This parame-
ter is not valid when a finite length axis is set.

• Setting range: 1 to 2

31

-1 [reference units]

Example: For rotating load, the value will be reset every 360

°.

360000

25

Maximum Number of
Absolute Encoder
Turns
(MAXTURN)

Set the maximum number of rotations for the absolute encoder when an absolute
encoder is used.

• Setting range: 1 to 2

31

-1 [rotations]

Refer to Chapter 8 Absolute Position Detection of Machine Controller MP920
User’s Manual: Design and Maintenance
(SIEZ-C887-2.1) for details.

99999

Table 6.2 Motion Fixed Parameters (cont’d)

No.

Name

Description

Factory

Setting

Motor shaft:
m turns

7 turns

3 turns

9 turns

4 turns

Load shaft: n turns

270

°

180

°

90

°

0

°

0

POSMAX