Yaskawa MP920 Motion Module User Manual

Page 139

Advertising
background image

4.2 Parameter List by Module

4-19

4

9

Machine Coor-
dinate System
Feedback Posi-
tion (APOS)

IL††08

-2

31

to 2

31

-1

1 = 1 reference unit
(1 = 1 pulse for pulse unit)
Note: Will not be updated if the machine is

locked.

11

Position Error
(PERR)

IL††0A

-2

31

to 2

31

-1

1 = 1 pulse

13

Speed Refer-
ence Output
Monitor
(SPDREF)

IW††0C

-32768 to 32767

1 = 0.01%

14

Speed Monitor
(NFB)

IW††0D

-32768 to 32767

1 = 0.01%

15

Not used.

IW††0E

16

Out of Range
Parameter
Number
(ERNO)

IW††0F

1 to 63
101 to 148

Motion setting parameter error number
Motion fixed parameter error number + 100

17

Cumulative
Rotations from
Absolute
Encoder
(ABSREV)

IL††10

0 to

±99999

1 = 1 rotation

19

Initial Incremen-
tal Pulses from
Absolute
Encoder
(IPULSE)

IL††12

-2

31

to 2

31

-1

1 = 1 pulse

21

Motion Com-
mand Response
Code
(MCMD-
RCODE)

IW††14

0 to 65535

Motion command that is currently executing.
(Refer to OW††20 for details.)

22

Motion
Command
Status
(MCMDSTS)

IW††15

Bit 0: BUSY

Command Executing Flag

Bit 1: HOLDL

Command Hold Completed

Bit 2: DEN

Distribution Completed

Bit 3: ZSET

Zero Point Setting Completed

Bit 4: EX_LATCH

External Positioning Signal Latched

Bit 5: FAIL

Command Error End

Bit 6: ZRNC

Zero Point Return Completed

Bits 7 to 15

Not used.

23

Number of Dig-
its Below
Decimal Point
Monitor
(DECNUMM)

IW††16

0 to 5

Copies motion fixed parameter Number of Dig-
its Below Decimal Point.

Table 4.4 Motion Monitoring Parameters (cont’d)

No.

Name

Register

Number

Setting Range

(Bit Name)

Meaning

Remarks

SVA

-01A

SVA

-02

A

SVB

-01

PO-

01

Advertising