Input signal selections – Yaskawa MP920 Motion Module User Manual

Page 295

Advertising
background image

6 SVB Module Specifications and Handling

6.2.5

Σ-II Series SERVOPACK Parameters

6-60

„

Input Signal Selections

The following table shows the input signal selections.

Parameter

No.

Digit Place

Name

Setting

Description

Factory

Setting

Pn50A

1st

Reserved

0 and 1

1

2nd

Reserved

0 to F

8: Disabled

3rd

Reserved

0 to F

8: Disabled

4th

P-OT Signal Mapping

0

Inputs from SI0 (CN1-40) input terminal.

Inputs from

SI2.

1

Inputs from SI1 (CN1-41) input terminal.

2

Inputs from SI2 (CN1-42) input terminal.

3

Inputs from SI3 (CN1-43) input terminal.

4

Inputs from SI4 (CN1-44) input terminal.

5

Inputs from SI5 (CN1-45) input terminal.

6

Inputs from SI6 (CN1-46) input terminal.

7

Enabled.

8

Disabled.

9

Inputs reverse signal from SI0 (CN1-40)
input terminal.

A

Inputs reverse signal from SI1 (CN1-41)
input terminal.

B

Inputs reverse signal from SI2 (CN1-42)
input terminal.

C

Inputs reverse signal from SI3 (CN1-43)
input terminal.

D

Inputs reverse signal from SI4 (CN1-44)
input terminal.

E

Inputs reverse signal from SI5 (CN1-45)
input terminal.

F

Inputs reverse signal from SI6 (CN1-46)
input terminal.

Pn50B

1st

N-OT Signal Mapping

0 to F

Same as P-OT Signal Mapping

Inputs from

SI3.

2nd

Reserved

0 to F

3rd

/P-CL Signal Mapping

0 to F

Same as P-OT Signal Mapping

Disabled

4th

/N-CL Signal Mapping

0 to F

Same as P-OT Signal Mapping

Disabled

Pn50C

1st

Reserved

0 to F

8: Disabled

2nd

Reserved

0 to F

8: Disabled

3rd

Reserved

0 to F

8: Disabled

4th

Reserved

0 to F

8: Disabled

Pn50D

1st

Reserved

0 to F

8: Disabled

2nd

Reserved

0 to F

8: Disabled

3rd

Reserved

0 to F

8: Disabled

4th

Reserved

0 to F

8: Disabled

Advertising