4 Parameters

4.2.1 Motion Fixed Parameters

4-6

7

Rated Motor Speed
Setting
(NR)

1 to 32000
(Default = 3000)

1 = 1 min

-1

8

Number of Feed-
back Pulses Per
Rotation
(FBppr)

Multiple of 4
between 4 and
65532
(Default = 2048)

1 = 1 pulse/rev

Set the value prior to
multiplying.

9

D/A Output
Voltage at 100%
Speed (V1)

0.001 to 10.000
(Default = 6 V =
6.000)

1 = 1 V

Number of Feed-
back Pulses Per
Rotation (For high-
resolution)

(Default = 2048)

1 = 1 pulse/rev

Set the value prior to
multiplying.

10

D/A Output
Voltage at 100%
Torque Limit
(V2)

0.001 to 10.000
(Default = 3 V =
3.000)

1 = 1 V

Valid only for the SVA (2
axes) Module.

11

Input Voltage at
100% Speed
Monitoring (A/D)
(MV1)

0.001 to 10.000
(Default = 6 V =
6.000)

1 = 1 V

Valid only for the SVA (2
axes) Module.

12

Not used.

13

DI Latch Signal
Selection
(DIINTSEL)

0 or 1
(Default = 0)

0: DI input signal
1: Pulse-C input signal

14

Additional Func-
tion Selections
(AFUNCSEL)

Bits 0 to 1:
Not used.

Bit 2: LIMITSEL

Limit Switch Signal Selection

0: Use OB††01F.
1: Use the DI signal.

Bit 3: LMT_LSEL Reverse Limit Signal Selection

for Zero Point Return

0: Use OB††21C.
1: Use the DI signal.

Bit 4: LMT_RSEL Forward Limit Signal Selection

for Zero Point Return

0: Use OB††21D.
1: Use the DI signal.

Bit 5: EMGSEL

Emergency Stop (DI) Signal
Selection

0: Emergency stop
(hard)
1: Deceleration stop
(soft)

Bit 6: ABSRDSEL Absolute Position Read at

Startup

0: Execute.
1: Do not execute.

Bit 7: MCMDSEL Motion Command Code

Selection

0: Not used.
1: Use.

Bit 9

Σ-II Series SERVOPACK

Selection

0: OFF
1: ON

Bits 12 to 15

Error Count Alarm Detection
Setting Coefficient

Setting range: 0 to 4

Table 4.2 Motion Fixed Parameters (cont’d)

No.

Name

Setting Range/

Bit Name

Meaning

Remarks

SVA

-01A

SVA

-02

A

SVB

-01

PO-

01