4 reverse rotation mode, 1 overview – Yaskawa MP920 Motion Module User Manual

Page 398

Advertising
background image

9 Application Precautions

9.4.1 Overview

9-18

9.4

Reverse Rotation Mode

This section describes the procedure used to set parameters when using the Reverse Rotation
Mode setting in a SERVOPACK connected to an SVA Module.

9.4.1

Overview

SERVOPACKs are equipped with a Reverse Rotation Mode that inverts the direction of Ser-
vomotor rotation without rewiring the Servomotor. Only the direction of Servomotor rota-
tion is inverted in Reverse Rotation Mode. Here the direction in which the axis moves (+, -)
is reversed, but nothing else changes.

„

Standard Setting Operation

„

Operation in Reverse Rotation Mode

The following parameters may or may not be set depending on the applicable type of Motion
Module and encoder when Reverse Rotation Mode control is used in machine or other con-
figurations.

The following section describes the parameters related to Reverse Rotation Mode operation.

Forward direction

Reverse direction

SGDB/SGDM/SGDS

SERVOPACK

CN1-42

CN1-43

Forward
direction
overtravel

Reverse
direction
overtravel

Servomotor

SGDB/SGDM/SGDS

CN1-42

CN1-43

Forward direction

Reverse direction

SERVOPACK

Forward
direction
overtravel

Reverse
direction
overtravel

Servomotor

Advertising