Analog servo alarms – Yaskawa MP920 Motion Module User Manual

Page 365

Advertising
background image

8.2 Alarms and Actions Taken

8-9

8

„

Analog Servo Alarms

IB††010 (SVALM) will turn ON if an alarm occurs with a SERVOPACK connected to an
SVA-01A or SVA-02A Module. Connect a Digital Operator to the SERVOPACK to check
alarm details.

Table 8.1 List of Analog Servo Alarms

Indicator

Alarm Name

Alarm

SGDA

SGDB

SGDM

A.00

Absolute Data Error

Absolute data cannot be received or an improper
absolute value was received.

Yes

Yes

No

A.02

Parameter Destruction

Incorrect sum check result for a parameter.

Yes

Yes

Yes

A.03

Main Circuit Detection
Error

Improper power circuit detection data.

No

No

Yes

A.04

Parameter Setting Error

Parameter setting exceeds the setting range.

Yes

Yes

Yes

A.05

Combination Error

Servomotor and SERVOPACK capacity combina-
tion is incorrect.

No

No

Yes

A.10

Overcurrent or Heat Sink
Overheat

Overcurrent flowed through the power transistor.
The heat sink overheated. (SGDM)

Yes

Yes

Yes

A.30

Regeneration Error

Regenerative processing circuit failed.

Yes

Yes

Yes

A.31

Position Error Pulse
Overflow

Position error pulse exceeded the parameter (over-
flow) value.

Yes

Yes

No

A.32

Regeneration Overload

Regenerative energy exceeds the capacity of the
regenerative resistor.

No

No

Yes

A.40

Overvoltage

Main circuit voltage is unusually high.

Yes

Yes

Yes

A.41

Undervoltage

Main circuit voltage is falling.

No

No

Yes

A.51

Overspeed

Servomotor rotation speed is unusually high.

Yes

Yes

Yes

A.70

Overload

Torque exceeds the rated level. (High and low load)

Yes

No

No

A.71

Overload (High Load)

Operation for several seconds to several tens of
seconds at torque significantly above the rated level.

No

Yes

Yes

A.72

Overload (Low Load)

Continuous operation at torque above the rated level.

No

Yes

Yes

A.73

Dynamic Brake Overload

Rotating energy with dynamic brake operation
exceeds dynamic brake resistor capacity.

No

No

Yes

A.74

Inrush Resistance
Overload

The main circuit power supply frequently turned ON
and OFF.

No

No

Yes

A.7A

Heat Sink Overheat

SERVOPACK heat sink overheated.

No

No

Yes

A.80

Absolute Encoder Error

Improper number of pulses per absolute encoder
rotation.

Yes

Yes

Yes

A.81

Absolute Encoder Backup
Error

All encoder power supplies OFF and position data
cleared.

Yes

Yes

Yes

A.82

Absolute Encoder
Checksum Error

Incorrect sum check results for encoder memory.

Yes

Yes

Yes

A.83

Absolute Encoder Battery
Error

Voltage dropped in the backup battery for the
absolute encoder.

Yes

Yes

Yes

A.84

Absolute Encoder Data
Error

Improper absolute data received.

Yes

Yes

Yes

A.85

Absolute Encoder
Overspeed

Encoder operated at high speed when power was
turned ON.

Yes

Yes

Yes

A.86

Encoder Overheat

Encoder internal temperature too high.

No

No

Yes

Advertising