7.3 PO-01 Parameters

7-49

7

7.3.3

Motion Monitoring Parameters

Table 7.11 Motion Monitoring Parameters

No. Name

Register

No.

Setting

Range/

Bit Name

Description

1

RUN Status
(RUNSTS)

IW††00

Monitors PO-01 Module operating status. The bit configuration is described below.

Bit 0

Not used.

Bit 1

Motion Setting
Parameter
Setting Error
(PRMERR)

Turns ON when one or more of the motion setting parameters
(OW††00 to OW††3F) is set outside the setting range.
In this case, the most recent motion setting parameter number that
caused the setting range alarm will be indicated at IW††0F:
Parameter Number Out of Range.

Bit 2

Motion Fixed
Parameter
Setting Error
(FPRMERR)

Turns ON when a motion fixed parameter is set outside the setting
range.
In this case, the most recent motion setting parameter number that
caused the setting range alarm plus 100 will be indicated at
IW††0F: Parameter Number Out of Range.
This parameter will turn OFF automatically if an ordinary motion
fixed parameter is set from the MPE720.

Bits 3 to 6

Not used.

Bit 7

Motion
Controller RUN
Ready
(SVCRDY)

Turns ON when RUN preparations for the PO-01 Module have been
completed.
The following may be reason why RUN preparations are not com-
pleted.

• Major damage has occurred.
• Axis that is not used was selected (motion fixed parameter set-

ting).

• Motion fixed parameter setting error.
• Motion fixed parameters are being changed.

Bit 8

Motion Control-
ler RUN
(SVCRUN)

Turns ON under the following conditions.

• IB††07: RUN Ready turns ON.
• OB††002: Position Control Mode Flag turns ON.
• OB††010: Excitation ON signal turns ON.

When this bit is ON and an alarm is generated, the axis will not
move even if a motion command is issued.
Clear the alarm, set the motion command to “NOP” for 1 scan or
more, and then set the motion command again.

Bits 9 to 12 Not used.

Bit 13

Positioning
Completed
Signal
(POSCOMP)

Turns ON when Distribution Completed (bit 2 of IW††15) turns
ON as follows:
|IL††08: Current Position

− IL††18: Machine Coordinate Sys-

tem Reference Position|

≤ OW††0E: Positioning Completed

Range

Bits 14, 15

Not used.