Yaskawa MP920 Motion Module User Manual

Page 233

Advertising
background image

5.4 SVA-01A and SVA-02A Parameters

5-91

5

35

Alarms
(ALARM)
(cont’d)

Bit 3

Positive
Software Limit
(SOTF)

Valid if IB††156: Zero Point Return Completed turns ON when the
positive software limit is enabled and a finite length axis is selected.

OW††20: Motion Command Code Interpolation

This bit turns ON when IL††18: Reference Position in Machine
Coordinate System + OL††26: Stopping Distance

≥ Positive Soft-

ware Limit (motion fixed parameter No. 27).

OW††20: Motion Command Codes Positioning, Feed. or Step

This bit turns ON when IL††18: Reference Position in Machine
Coordinate System

≤ Positive Software Limit (motion fixed param-

eter No. 27).

Bit 4

Negative
Software Limit
(SOTR)

Valid if IB††156: Zero Point Return Completed turns ON when the
negative software limit is enabled and a finite length axis is selected.

OW††20: Motion Command Code Interpolation

This bit turns ON when IL††18: Reference Position in Machine
Coordinate System + OL††26: Stopping Distance

≤ Negative

Software Limit (motion fixed parameter No. 29).

OW††20: Motion Command Codes Positioning, Feed. or Step

This bit turns ON when IL††18: Reference Position in Machine
Coordinate System

≥ Negative Software Limit (motion fixed

parameter No. 29).

Bit 5

Not used.

Bit 6

Positioning
Time Over
(TIMEOVER)

Turns ON if bit 13 of IW††00: Positioning Completed Signal does
not turn ON when the Positioning Completed Check Time
(OW††34) is exceeded after bit 2 of IW††15: Distribution Com-
pleted is turned ON.

Bits 7 to 9

Not used.

Bit 10

Control Mode
Error
(MODERR)

Turns ON when a move command is set at OW††20: Motion Com-
mand Code in a mode other than Position Control Mode (OB††002
is OFF).

Bit 11

Zero Point Not
Set
(ZSET_NRDT)

Turns ON when an attempt is made to execute one of the following
motion commands with the bit 3 of IW††15: Zero Point Setting
Completed Signal turned OFF.

• POSING
• EX_POSING
• INTERPOLATE
• ENDOF-INTERPOLATE
• LATCH

It is valid when infinite length axis is set when an absolute encoder is
used.

Bits 12 to
16

Not used.

Bit 17

ABS Encoder
Count Exceeded

Turns ON when the absolute encoder count exceeds the range that the
Motion Module can handle.
It is valid if a finite length axis is set when an absolute encoder is used.

Bit 18

Broken PG Wire
Error

Turns ON when a broken PG wire is detected.
It is valid when the pulse calculation method selection is set to the A/
B mode in motion fixed parameters.

Bits 19 to
31

Not used.

Table 5.7 Motion Monitoring Parameters (cont’d)

No.

Name

Register

Number

Setting Range/

Bit Name

Description

Advertising