2 Motion Control

2.3.1 Prerequisites for Position Control

2-26

2.3

Position Control

This section describes the prerequisites for position control, and position control without using
motion commands.

2.3.1

Prerequisites for Position Control

With position control, the axis is moved to the target position, stops there, and holds that
position (servo clamp).

An incremental encoder or a Yaskawa absolute encoder is used as the position detector.
When a Yaskawa absolute encoder is used, the absolute position is stored, even when the
power for the machine (positioning device) is disconnected. Therefore, when the power is
turned ON again, the zero point return operation is not required.

There are two position control methods. One method uses motion commands (OW††20),
and the other method does not use motion commands.

Whether or not motion commands (OW††20) are to be used is set in the motion parame-
ters shown in the following table.

Note: When bit 7 (motion command code selection) of motion fixed param-

eter No. 14 (Additional Function Selections) is not selected for use
and bit 8 (motion command code enable/disable) of RUN Mode Set-
tings (OW††00) motion setting parameter is set to “1” (= enabled),
the axis is controlled without motion commands (OW††20).

The position control mode is available with all Motion Modules. However, it can be used for the SVB-
01 and PO-01 Modules only when motion command code is enabled.

The following table shows position control mode availability for each Motion Module.

Motion Parameter

Motion Command

(OW††20) Not

Used

Motion Command
(OW††20) Used

Motion fixed parameter No. 14
Bit 7 of Additional Function Selections
(Motion Command Code Selection)

0 (= Not used)

1 (= Used)

Motion setting parameter
Bit 8 of RUN Mode Settings (OW††00)
(Motion Command Code Enable/Disable)

0 (= Disabled)

1 (= Enabled)

Motion

Module

Position Control Mode

Motion Command Code

Enabled

Motion Command Code

Disabled

SVA-01A

Available

Available

SVA-02A

Available

Available

SVB-01

Available

Not available

PO-01

Available

Not available

IMPORTANT