10.5 CNTR-01 Counter Module Connections

10-35

10

„

5-V Differential Pulse Generators

The connections to a 5-V differential pulse generator are shown in the following diagram.

• Use a standard JEPMC-W6060-†† cable to connect the CNTR-01 Module and the Junction Ter-

minal Block.

• Use shielded twisted-pair cable to connect the Junction Terminal Block and the Pulse Generator.
• Do not connect input terminals that will not be used.

0V

75ALS1177

+5PA1

L

330

Ω

2.2k

47k

47k

-5PA1

L 2.2k

+5PB1

L

330

Ω

2.2k

47k

47k

-5PB1

L 2.2k

EN

PIASEL

Vb

75ALS1177

+5PC1

L

330

Ω

2.2k

47k

47k

-5PC1

L 2.2k

EN

PIASEL

Phase B

Phase A

Phase C

GND

CN1

CNTR-01

+5V

(Connector shell)

Pulse Generator

Junction Terminal Block