10.5 CNTR-01 Counter Module Connections
10-35
10
5-V Differential Pulse Generators
The connections to a 5-V differential pulse generator are shown in the following diagram.
• Use a standard JEPMC-W6060- cable to connect the CNTR-01 Module and the Junction Ter-
minal Block.
• Use shielded twisted-pair cable to connect the Junction Terminal Block and the Pulse Generator.
• Do not connect input terminals that will not be used.
0V
75ALS1177
+5PA1
L
330
Ω
2.2k
47k
47k
-5PA1
L 2.2k
+5PB1
L
330
Ω
2.2k
47k
47k
-5PB1
L 2.2k
EN
PIASEL
Vb
75ALS1177
+5PC1
L
330
Ω
2.2k
47k
47k
-5PC1
L 2.2k
EN
PIASEL
Phase B
Phase A
Phase C
GND
CN1
CNTR-01
+5V
(Connector shell)
Pulse Generator
Junction Terminal Block