Yaskawa MP920 Motion Module User Manual

Page 293

Advertising
background image

6 SVB Module Specifications and Handling

6.2.5

Σ-II Series SERVOPACK Parameters

6-58

Pn003
Function
Selection
Application
Switches 3

1st and 2nd

Analog Monitor 1
Torque reference moni-
tor
Analog Monitor 2
Speed reference monitor

0

Motor speed: 1 V/1000 r/min

Monitor 1:

Torque

reference

Monitor 2:

Motor speed

1

Speed reference: 1 V/1000 r/min

2

Torque reference: 1 V/100%

3

Position error: 0.05 V/pulse

4

Position error: 0.05 V/100 pulses

5

Reference pulse frequency [r/min conver-
sion]: 1 V/1000 r/min

6

Motor speed

× 4: 1 V/250 r/min

7

Motor speed

× 8: 1 V/125 r/min

3rd

0

4th

0

Pn004
Function
Selection
Application
Switches 4

1st

0 and 1

0

2nd

0 and 1

0

3rd

0

4th

0

Pn005
Function
Selection
Application
Switches 5

1st

0

Uses the brake of the SERVOPACK.

Uses the

brake of the

SERVO-

PACK.

1

Uses BRK_ON and BRK/OFF signals from
the controller.

2nd

0

3rd

0

4th

0

Pn10B
Gain-
related
Application
Switches

1st

Mode Switch Selection

0

Uses internal torque reference as the condi-
tion (Level setting: Pn10C).

Uses internal

torque

reference.

1

Uses speed reference as the condition (Level
setting: Pn10D).

2

Uses the acceleration as the condition (Level
setting: Pn10E).

3

Uses position error pulse as the condition
(Level setting: Pn10F).

4

No mode switch function available.

2nd

Speed Loop Control
Method

0

Speed Loop Control Method PI control

PI control

1

Speed Loop Control Method IP control

3rd

0

0

4th

0

0

(cont’d)

Parameter

No.

Digit Place

Name

Setting

Description

Factory

Setting

Advertising