5 SVA Module Specifications and Handling

5.4.2 Motion Setting Parameters

5-74

22

Speed Refer-
ence Setting
(NREF)

OW††15

-32768 to 32767 „ Speed Reference Output Mode

Set the speed reference in 0.01% units.

„ Position Control Mode

Set the speed reference in a steady state in 0.01% units.

„ OW††20: Motion Command Code Used in Position

Control Mode

Set the rapid traverse speed in 0.01% units (percentage
of the rated motor speed) when the Speed Reference
Selection (OB††1D) is set to 1.

„ Phase Control Mode

Set the standard speed reference in 0.01% units.
D/A output = (OW††15: Speed Reference Setting

× D/

A Output Voltage at 100% Speed (fixed parameter 9)) /
10000
Example:
When the D/A Output Voltage at 100% speed = 6 V and
the speed reference = 100%, then (10000

× 6 V) / 10000

= 6.0 V is output.

0.00

23

Phase Bias
Setting
(PHBIAS)

OL††16

-2

31

to 2

31

-1

Set the number of compensation pulses in Phase Control
Mode. Use this parameter to compensate for reference
pulses in control systems with no rigidity or gain.

0

25

Speed
Compensation
Setting
(NCOM)

OW††18

-32768 to 32767

Set the speed compensation in 0.01% units in Phase Con-
trol Mode. OW††18: Speed Compensation Setting is
valid even in Phase Control Mode if bit 10 of OW††21:
Speed Compensation during Position Control is ON.

0

26

Proportional
Gain Setting
(PGAIN)

OW††19

0 to 32767

Set proportional gain for PI control in 0.1 units in Phase
Control Mode.

30.0

27

Integral Time
Setting (Ti)

OW††1A

0 to 32767

Set the integral time for PI control in 1 ms units in Phase
Control Mode. Integration will be reset if the integral
time is set to 0.

300
(300 ms)

28

Torque Refer-
ence Setting
(TREF)

OW††1B

-32768 to 32767

Set the torque reference in 0.01% units in Torque Refer-
ence Output Mode.
D/A output = (OW††1B: Torque Reference

× D/A Out-

put Voltage at 100% Torque Limit (fixed parameter 10)) /
10000
Example:
When the D/A Output Voltage at 100% Torque Limit = 3
V and the torque reference = 50%, then (5000

× 3 V) /

10000 = 1.5 V is output.

Note: Valid only for SVA-02A (2-axis) Module.

0.00

Table 5.6 Motion Setting Parameters (cont’d)