Yaskawa MP920 Motion Module User Manual

Page 271

Advertising
background image

6 SVB Module Specifications and Handling

6.2.2 Motion Setting Parameters

6-36

54

Servo Driver
Cn Constant
No. (Cn_No.),
Current Servo
Driver Alarm
Monitor No., or
Servo Driver
Alarm History
Monitor No.

OL††35

This parameter can be used in the following three ways.

„ Servo Driver Cn Constant No. (Cn_No.):

Valid when Motion Command Code (OW††20) is
set to 17 (CN_RD) or 18 (CN_WR).
Bits 0 to 11: Cn constant No.
Bits 12 to 15: Number of words

„ Current Servo Driver Alarm Monitor No.:

Valid when Motion Command Code (OW††20) is
set to 19 (ALM_MON). Specify a number between 0
and 5. The alarm code corresponding to the specified
monitor number is stored in IW††24.

„ Servo Driver Alarm History Monitor No.:

Valid when Motion Command Code (OW††20) is
set to 20 (ALMHIST_MON). Specify a number
between 0 and 9. The alarm code corresponding to the
specified monitor number is stored in IW††24.

0

55

Cn Constant
Change Data
(Cn-DAT)

OL††36

-2

31

to 2

31

-1

Valid when Motion Command Code (OW††20) is set to
18 (CN_WR).

0

57

Lower-place
Two Words of
Encoder
Position at
Shutdown or
Position Buffer
Access Num-
ber

OL††38

-2

31

to 2

31

-1

This parameter is used in the following two ways and
should be used with care.

„ Lower-place 2 Words of Encoder Position at Shut-

down
This parameter is valid when the motion fixed parame-
ter: Encoder Selection is set to absolute encoder (= 1)
and motion fixed parameter: Axis Selection (bit 5 of
the Motion Controller Function Selection Flags) is set
to an infinite length axis (= 1).
When bit 2 of OW††2D: ABS System Infinite
Length Position Control Data Load Request turns ON,
the data set at this parameter will be treated as the
lower-place two words of the encoder position at shut-
down.

„ Position Buffer Access Number

When bit 14 of OW††21: Position Buffer Write or
bit 15 of OW††21: Position Buffer Read turns ON,
the data set at this parameter will be treated as the
buffer number of the position buffer. The setting range
for this parameter is 1 to 256 and it is not valid if set to
“0.”

0

Table 6.3 Motion Setting Parameters (cont’d)

No.

Name

Register

Number

Setting Range/

Bit Name

Description

Factory

Setting

Advertising