Yaskawa MP920 Motion Module User Manual

Page 349

Advertising
background image

7.3 PO-01 Parameters

7-47

7

46

Position Con-
trol Flags
(POSCTRL)

OW††2D

Set the functions related to position data managed by PO-01 Modules. The bit config-
uration is described below.

Bit 0

Machine Lock
Mode Setting
(MLK)

In Machine Lock mode, only the Machine Coordi-
nate System Calculation Position (CPOS)
(IL††02) is updated without actually moving the
axis.
A change in this bit will be effective when
IB††152: Distribution Completed turns ON.
0: OFF, 1: ON

0

Bit 1

Request for
the Preset
Number of
POSMAX
Turns
(TPRSREQ)

Request for the preset number of POSMAX turns.
0: OFF, 1: ON

• With an infinite length axis, a turn is counted

every time the position value exceeds POSMAX
and the count is stored at monitor parameter
IL††1E: Number of POSMAX Turns.

• The number of turns can be preset at setup param-

eter OL††30: Preset Data for Number of POS-
MAX Turns by turning ON the Request for the
Preset Number of POSMAX Turns Flag.

Related Parameters:

• Fixed parameter 22:

Maximum Value for Infinite Length Counter

• Setting parameter OL††30:

Preset Data for the Number of POSMAX Turns

• Monitoring parameter IL††1E:

Number of POSMAX Turns

0

Bits 2 to
15

Not used.

Set to “0.”

0

47

Workpiece
Coordinate
System Offset
(OFFSET)

OL††2E

-2

31

to 2

31

-1

Always set this parameter to “0.” It is not used
directly by PO-01 Module.

0

49

Preset Number
of POSMAX
Turns Data
(TURNPRS)

OL††30

-2

31

to 2

31

-1

IL††1E: POSMAX Number of Turns can be preset
with preset data by turning ON OB††2D1: Request
for Preset Number of POSMAX Turns.
It is used in situations such as when resetting the
number of turns to “0.”

0

51

Not used.

OW††32

Set to “0.”

0

52

Zero Point
Position Output
Width
(PSETWIDTH)

OW††33

0 to 65535

Set the zero point position range. IB††171: Zero
Point Position will turn ON if 0

≤ |IL††18: Refer-

ence Position in Machine Coordinate System|

≤ Zero

Point Position Output Width when IB††156: Zero
Point Return Completed Status turns ON.

10

53 to
56

Not used.

OW††34

Set to “0.”

0

Table 7.10 Motion Setting Parameters (cont’d)

No. Name

Register

Number

Setting

Range/

Bit Name

Description

Factory

Setting

Advertising