Yaskawa MP920 Motion Module User Manual
Page 405

10 CNTR-01 Module Specifications and Handling
10.1.2 Handling
10-4
The following table shows the LED indicators when an error occurs in a CNTR-01 Module.
Pulse Input Connector 1
5-V Differential Pulse Input Connector
Error (Detected by Online Self-
diagnostic Function)
LED Indicator
RUN
ERR
CH1 to CH4
ROM Diagnostic Error
Lit
Flashes once
Indefinite
RAM Diagnostic Error
Lit
Flashes twice Indefinite
Shared Memory Diagnostic Error
Lit
Flashes 3
times
Indefinite
CPU Built-in Timer Diagnostic
Error
Lit
Flashes 4
times
Indefinite
Timer Diagnostic Error
Lit
Flashes 5
times
Indefinite
General Illegal Command Interrupt
Not lit
Flashes once
Indefinite
Slot Illegal Command Interrupt
Not lit
Flashes twice Indefinite
CPU Address Error Interrupt
Not lit
Flashes 3
times
Indefinite
DMA Address Error Interrupt
Not lit
Flashes 4
times
Indefinite
User Brake Interrupt
Not lit
Flashes 5
times
Indefinite
Trap Command Interrupt
Not lit
Flashes 6
times
Indefinite
Watchdog Timer Expired
Lit
Flashes 15
times
Indefinite
This connector is used to connect 5-V differential pulse input signal
terminals to the CNTR-01 Module.
Number of Channels: 4
CN1