Setting parameters for mechatrolink communications – Yaskawa MP920 Motion Module User Manual

Page 298

Advertising
background image

6.2 SVB-01 Parameters

6-63

6

„

Setting Parameters for MECHATROLINK Communications

The following table shows the setting parameters for MECHATROLINK communications.

Parameter

No.

Digit Place

Name

Setting

Description

Factory

Setting

Pn800

1st

MECHATROLINK
Communications Check
Mask (For debugging)

0

Normal status

Normal

status

1

Ignores communications errors.

2

Ignores WDT errors.

3

Ignores both communications errors and
WDT timeout errors.

2nd

0

3rd

0

4th

0

Pn801

1st

Software Limit Function

0

Forward and reverse software limit enabled.

Enables the

soft limit

function

1

Forward software limit disabled.

2

Reverse software limit disabled.

3

Software limit disabled in both directions.

2nd

Software Limit
Operation Selection

0

Operates on absolute positions (APOS) in
machine coordinate system.

Absolute

positions in

machine

coordinate

system

1

Operates on absolute positions (APOS) in
reference coordinate system.

3rd

Software Limit Check by
References

0

No software limit check by references.

No software

limit check

1

Software limit check by references.

4th

0

Pn802

1st

SV_ON Command Mask

0

SV_ON and SV_OFF commands enabled.

Commands

enabled

1

Always servo ON.

2nd

SENS_ON Command
Mask

0

SENS_ON and SENS_OFF commands
enabled.

Commands

enabled

1

Always SENS_ON.

3rd

0

4th

0

Pn813

1st

Option Monitor 1
Selection

0

Analog monitor 1 (Pn003.0)

Pn003.0

1

Analog monitor 2 (Pn003.1)

2

Initial multiturn data (IMTDATA)

3

Encoder count value (PGCNT)

2nd

Option Monitor 2
Selection

0 to 3

Same as Option Monitor 1 Selection

Pn003.1

3rd

0

4th

0

Pn816

0

Homing Mode Setting

0

Forward

Forward

1

Reverse

1

0

2

0

3

0

Advertising