2 motion alarm configuration, List of motion program alarm codes – Yaskawa MP920 Motion Module User Manual

Page 376

Advertising
background image

8 Troubleshooting

8.2.2 Motion Alarm Configuration

8-20

8.2.2

Motion Alarm Configuration

The following illustration shows the motion alarm configuration stored in the alarm output
register that is set in the Group Definition Window.

„

List of Motion Program Alarm Codes

The following table lists the Motion Program Alarm Codes. Use HEX(H) for the Display
Mode when displaying the register list.

Name

Alarm Code

Contents

Remedy

Program
Alarm

0

No alarm

Check the alarm
details on the instruc-
tions of the motion
program that was
being run when an
alarm occurred.

1

2

Division-by-zero error

3

4

10h

Circumference specified alarm for
radius specification

11h

Exceeded the interpolation feed speed

12h

No interpolation feed speed specified

13h

Out of range after changing acceleration
and deceleration parameters

14h

Circular length exceeds LONG_MAX

15h

No vertical axis specified for circular
plane specification

16h

No horizontal axis specified for circular
plane specification

17h

Exceeded the exponent axis

18h

Exceeded the specified number of turns

19h

Radius exceeds LONG_MAX

1Ah

Center point specification error

1Bh

Emergency stop command executing

1Ch

Linear interpolation block distance trav-
eled exceeds LONG_MAX

1Dh

FMX not defined

1Eh

Address T outside the range

1Fh

Address P outside the range

20h

REG data error

lnformation on the axis
where the alarm
occurred (1 to 14)

Alarm code

Axis alarm

bit15

bit12

bit8

bit7

bit0

Advertising