5 SVA Module Specifications and Handling

5.4.2 Motion Setting Parameters

5-70

Table 5.6 Motion Setting Parameters (cont’d)

No.

Name

Register

Number

Setting Range/

Bit Name

Description

Factory

Setting

11

Approach
Speed Setting
(Napr)

OW††0A

0 to 32767

Set the approach and creep speed when returning to the
zero point ((ZRET).
The setting unit depends on OB††01D: Speed Refer-
ence Selection.

1. When OB††01D = 0 (specified in reference units)

1 = 10

n

reference units/min (n = number of digits

below the decimal point)
Pulse unit: 1 = 1000 pulses/min
mm unit: 1 = 1 mm/min
deg unit: 1 = 1 deg/min
Inch unit: 1 = 1 inch/min

2. When OB††01D = 1 (specified in reference units)

When OB††01D = 1 (% specified), then 1 = 0.01%
(percentage of the rated rotation speed).

Note: A percentage is specified regardless of the set-

ting at OB††1D in Zero Point Return Mode.

0

12

Creep Speed
Setting (Nclp)

OW††0B

0 to 32767

0

13

Linear Acceler-
ation Time
Constant
(NACC)

OW††0C

0 to 32767

Set the linear acceleration/deceleration time for Speed,
Position Control, and Zero Point Return Modes.
Unit: ms
Set acceleration time from 0% to 100% (rated motor
speed).
The deceleration time is the same as the acceleration
time.

0

14

Linear Decel-
eration Time
Constant
(NDEC)

OW††0D

0 to 32767

0

0

1.

2.

3.

4.

Reverse direction

←→ Forward direction

Speed
reference

Dog
(Deceleration LS)

Zero point signal
(Phase-C pulse)

Rapid traverse
speed

Approach
speed

Creep speed

Zero point return
position

Zero point

Zero point return final
travel distance

Time

NREF

Time

(t)

Speed

(%)

NR

(100%)

Speed
reference

0

NACC

NDEC