7 PO-01 Module Specification and Handling

7.2.5 Emergency Stop

7-30

5. Turn ON and then OFF the alarm clear (OW††00 bit 6).

Note: If an emergency stop signal (DI04) is input while the axis is moving,

then Excitation OFF (IL††22 bit 5) will turn ON. Operation cannot
be restarted in this case. Excitation OFF (IL††22 bit 5) can be can-
celed (turned OFF) by turning ON, and then OFF the Alarm Clear
(OW††00 bit 6).

The above procedure completes preparations for restarting operation. After this is com-
pleted, restart operation using the normal run sequence.

„

Procedure for Restarting Operation

This section describes the procedure for restarting normal operation.

1. Turn ON the Position Control Mode (OW††00 bit 2).

This is not required if the Position Control Mode is already ON.

2. Turn ON Excitation ON (OW††01 bit 0).

3. Set zero point return (ZRET) in the motion command code and return to the zero point.

Note: The position controlled by the PO-01 Module (CPOS: IL††02) and

the actual machine system position do not have to be the same.

4. The normal operation program will be executed.

Operation will remain stopped as long as Emergency Stop/Deceleration Stop Signal (IW††01 bit 4)
is ON so be sure to cancel the emergency stop.