Yaskawa MP920 Motion Module User Manual

Page 35

Advertising
background image

2.2 Control Modes

2-9

2

1. Set the motion fixed parameters according to the user’s machine.

* 1. Valid only with an SVB-01 Module.
* 2. Valid only with an SVA-02A Module.

2. Set the motion parameters to be used in the speed reference output mode.

The following three methods can be used to set the motion setting parameters.

• Using the MPE720 Setting Parameter Window
• Using a ladder logic program
• Using a motion program

* Valid only with an SVA-02A Module.

In the examples, SERVOPACK is used as axis 1 of Module No. 1. When the Module
number and the axis number are different, see 4.1.2 Modules and Motion Parameter
Registers
, and change the register numbers.

3. Select the Speed Reference Output Mode (NCON) (bit 0 of OW††00).

Table 2.1 Examples of Fixed Parameters

No.

Name

Setting Range

Meaning

Setting

Example

7

Rated Motor Speed Setting

1 to 32000

Rated motor speed

3000 min

-1

8

Number of Feedback Pulses per
Motor Rotation

4 to 65532

Number of pulses
before multiplication

2048

9

D/A Output Voltage at 100%
Speed

0.001 to 10.000

0.001 = 0.001 V
1 = 1 V

6.000 V

Number of Feedback Pulses per
Motor Rotation
(For high-resolution) *

1

4 to 2147483647

1 = 1 pulse/rev

2048 pulses/
rev

10

D/A Output Voltage at 100%
Torque Limit*

2

0.001 to 10.000

0.001 = 0.001 V
1 = 1 V

3.000 V

Table 2.2 Examples of Setting Parameters

Name

Register No.

Setting

Range

Meaning

Setting

Example

Positive Torque Limit
Setting (TLIMP)*

OW††02

-327.68 to
327.67

0.01 = 0.01%
1 = 1%

-100.00
(-100.00%)

Positive Speed Limit-
er Setting (NLIMP)

OW††04

0.00 to
327.67

0.01 = 0.01%
1 = 1%

130.00
(130.00%)

Negative Speed Lim-
iter Setting (NLIMN)

OW††05

0 to 327.67

0.01 = 0.01%
1 = 1%

130.00
(130.00%)

Linear Acceleration
Time Constant
(NACC)

OW††0C

0 to 32767

Linear acceleration time con-
stant (ms) at speed pattern
generation

1000
(1 second)

Linear Deceleration
Time Constant
(NDEC)

OW††0D

0 to 32767

Linear deceleration time
constant (ms) at speed pat-
tern generation

1000
(1 second)

Filter Time Constant
Setting (NNUM)

OW††14

0 to 255

For simple S-curve accelera-
tion

0

Speed Reference
Setting (NREF)

OW††15

-327.68 to
327.67

Speed reference value
0.01 = 0.01%
1 = 1%

50.00
(50.00%)